| Home | E-Submission | Sitemap | Contact Us |  
top_img
J Radiat Prot > Volume 16(1); 1991 > Article
Journal of Radiation Protection 1991;16(1):43-0.
방사선 피폭선량프로그램 DOS, LIMCAL 및 PABLM의 비교
박희성;조원진;한경원;박헌휘;
Comparison of Dose Assessment Programs; DOSE, LIMCAL and PABLM
Park, Hee-Seoung;Cho, Won-Jin;Han, Kyoung-Won;Park, Hun-Hwee;
ABSTRACT
A comparison study is performed on dose assessment programs including DOSE, LIMCAL, and PABLM, DOSE is a program developed for preliminary safety assessments of the low- and intermediate- level radioactive waste disposal, and the others are existing programs applicable to similar calculations. The results show acceptable agreement within an order of magnitude(mrem/yr) except for C-14 and Pu-239. PABLM results higher dose for C-14 while lower value for Pu-239 in comparison with those from DOSE or LIMCAL. It is found that the discrepancy in C-14 is due to difference in transport model introduced and that in Pu-239 is from the different value of dose conversion factor to each program.
TOOLS
PDF Links  PDF Links
Full text via DOI  Full text via DOI
Download Citation  Download Citation
Share:      
METRICS
1,012
View
4
Download
Editorial Office
#319, Hanyang Institute of Technology Bldg., 222 Wangsimni-ro, Seongdong-gu,Seoul, Republic of Korea
Tel: +82-2-2297-9775   Fax: +82-2-2297-9776
Email: jrpr.editorial@gmail.com
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © by Korean Association for Radiation Protection. Developed in M2PI