ABSTRACT
The 42 patients with carcinoma of the cervix, performed intracavitary radiotherapy, were analysed the doses at points A and B comparing to the mghr prescription. The doses at points A and B were calculated by PC-12 computer planning system. Correlation coefficienty between doses at points A and B and the mghr prescription are 0.82 (p<0.001) and 0.90 (p<0.001) respectively. The slope of the point A line is 0.70 and the slope of the point B is 0.21. Therefore, the dose at point A is approximately 3/4 the mghr prescription and the dose at point B is approximately 1/4 the mghr precription.